1.本品采用日本高精度進口傳感器,穩定性好。
2.進口傳感器可以有效防止咖啡,煙味所帶來的飄逸。
2.獨立專業的吹氣方式,喉舌折疊式,使氣流更穩定,精確度更高。
3.無毒一次性吹嘴,乾凈 衛生。
4.測試范圍0.00-2.00G/L。
5.重復性 :可連續吹氣50次,輸出數值誤差正負0.01%BAC
6. 精確度:在整個量程范圍內正負誤差0.01%BAC
7.預熱時間: 20-30S
8.測試時間:5S
9.顯示結果:10S
User’s Manual
Digital Display Alcohol Concentration Test Meter
Model: AD-6000NS
Precautions 1
● Thank you for selecing and purchasing AD-6000NS digital display alcohol concentration test meter. Please read this manual carefully to ensure that you can use the product correctly.
● This device is a healthcare product; it is intended to control overdrink of alcohol so as to keep you fit, through testing the alcohol in your breath and calculating the content of alcohol in the blood via microcomputer. The product is applicable to family healthcare as well as for reference in determining whether the driver is driving after drinking.
● The test result may be affected by a number of aspects such as environmental temperature, various gases in the air and smoking, etc. the result shall, therefore, be only for reference and shall not be regarded as the justification of driving after drinking.
● No matter whether you have consumed this product, its manufacturer and appropriate agents shall be not responsible for any traffic accident arisen due to ethanol or other accidents happened under the related regulations and rules.
● As people’s breath contains some fermentable gases (from stomach and intestines), so some gases may even be tested out under no drink circumstance.
● When after drinking, it is recommended to last after 20 minutes, it is because 20 minutes is approximately for alcohol to be absorbed into blood from the digestive organs, and residual alcohol remaining in the mouth takes this long to dissipate.
● For accurate result, do not repeat neat testing with in 3 minutes after time.
● Do not somke and eat for 20 minutes prior testing.
● Do not use any excitant substances near the tester, such as paing, insecticedes, alcohols.
● If the device has been performed for five times successively, please stop for two minutes and then use it again.
● Do not drive after drinking!
Preparation Before Using 2
l After opening the package, please check the parts and components below. If any one is absent, please contact its dealer.
l Accessories
1.One AD-6000NS LED digital display alcohol concentration detector
2. One User Manual
3. Three AA alkaline batteries. .(not included)
4. 6 air-blowing pipes.
● Battery Installation
Install two 1.5V AA alkaline batteries or two batteries with same specification into the battery case in a right way (a s shown in figure 1) per the mark “+” and “-” on the case, and then close the cover well (as shown in figure 2)
● Battery Replacement
If the yello LED on the LCDflashes, it indicates the battery electricity is not enough and the batteries need to be replaced, in order to ensure the test accuracy. Open the battery cover and take out the batteries, and reinstall the new batteries with same specification (as shown in figure 3). Make sure to keep the old batteries out of children’s reach, please dispose the useless batteries according to the local regulations.
How to use the alcohol tester 3
l Operational Procedure:
l Wait
l Press the power button about 2 seconds, the alcohol tester LCD will tun on with one beep sound.
l The:”wark up” symbol is displayed and the 150 to 000(or 15 to 00) countdown is started that indicate the testeris in wark up mode.
l NOTE
l If first wark up is defeated, the tester will be reset automatically and wark up again for 1-3 times.
l It always has a large number of gas&impurity adsorbed on the surface of alcohol sensor, when first time taking out the tester from the packaging , or after long time no using for the tester, it need more time for cleaning and wark up the alcohol sensor, you should repress the power button and retry several times If possible.
l TEST
l The “BLO”symbolis displayed when wark-up is succeed, and the 100 to 000 countdown is started that indicate the tester is in testing mode.
l Near and blow into the breath inhalefor 3-5 seconds.
l Read the tester result from the alcohol tester lcd.
l Push the power button and hold 3s,the buzzer sounds “B” one times, it is warming up and counting down from 150 about 15s. It will start to “BLOW” when it count down to “000”.
l It will sounds and the green LED will light on and display “BLO” after counting down, it means you can start to test. “BLO” will shine about 10s. Confirm to blow within this 10s.
l Blow to the breath inlet about 5s, There is a long sound if there is alcohol, and it will display 003,002,001. After this, the result will show on. only green LED shines and there are short sound “B,B,B” if the result is between 0.00-0.05. only red LED shines and there are long sound “B,B,B” if the result is more than 0.05. The result will remain 15s, and then it will turn off.
l If there is no alcohol, it will display 0.00 after 10s shining “BLO”.
l It will auto turn off if there is no alcohol or no testing within 30s after turning on.
Auto power off 4
- After the result be display for about 10 seconds, the “off” symbol will appear 2 seconds and the alcohol tester be turned off.
- If wark up is defeated, the tester will automatically turned off.
Alarm Setting 5
□0.20‰BAC □0.30‰BAC □0.40‰BAC
□0.50‰BAC □0.60‰BAC □0.70‰BAC
□0.80‰BAC □0.90‰BAC □1.00‰BAC
Maintenance 6
l Do not use these cleansers such as benzene, thinner or petrol to clean the product to avoid damaging its surface.
l Do not fall it down or strike, otherwise malfunction may be caused.
l Do not try to repair, rebuild or dismantle any parts except for the battery replacement.
l When not use the device for a long time, you are recommended to take out the batteries to prevent the damage due to battery leakage.
Performance Parameter 7
l Measure range: 0.00-0.20%BAC;0.00-2.00‰BAC;0.00-2.00g/l;0.00-1.00mg/l Acquiescence is(0.00-2.00‰BAC)
l Alarming Level: 0.05%BAC; 0.5‰BAC; 0.5g/l; 0.25mg/l
l Accuracy: ±0.01%BAC; ±0.1‰BAC; ±0.05 mg/l
l Figure size: Length 120mm
Width 46mm
Height 15mm
l weight: 45g
l Battery: 2×1.5V(AA battery)
l Current consumption: working current≤180mA
l Quiescent Current≤40μA
l Environmental temperature: -10℃~50℃
l Environmental humidity: ≤95% NO Dews
l Battery expectancy time:≥300 Times
Professional Series AD-6000NS
|
|
AD-6000NS is our best selling model in the series. |
Specifications
Certifications | DOT (OEM), CE mark. (DOT approval in US is widely recognised as an industry standard in evaluating alcohol tester's accuracy in the market) |
B.A.C detection range | 0.00 – 0.20%BAC(0.00 – 1.0MG/L BRAC) |
Accuracy | +/- 0.1 ‰ BAC at cal. point |
Increment unit | 0.1 ‰ BAC |
Display | 3 digit LED display |
DECT™ Technology | maintain stability of accuracy in dynamic conditions (temperature, humidity, storage time) |
EVT™ Technology | auto monitor of air in-flow, ensure only deep lung sample is obtained for maximum accuracy |
Sensor self diagnostic function 1 | automates self 'health-check' for re-calibration estimation |
Sensor self diagnostic function 2 | automatic identifies un-qualified blowing sample by user |
alert System | Visual and audio alert system when BAC level exceed legal limit |
alert level pre-calibrated point | 0.3, 0.5,0.8 ‰ BAC / 0.03, 0.05,0.08 % BAC |
Misc features | Warm up time countdown, Fast response, auto power-save mode, low battery indicator, Compact design with foldable mouthpiece |
Operation mode | 1-button operation |
Re-calibration | 'EZ-CAL' feature for user friendly re-calibration |
Power | 2 X AA alkaline battery |
Dimensions | 1250x 46x 15mm |
Weight | 55 grams |
Material | ABS Impact Resistant Material |
Batterylife | 200 to 300 tests * |
Sensor | Sensitive Semiconductor |
Warmup time | 15 Seconds |
Blowing time | 5 seconds |
Response time | 4-5 seconds |
Air sample | 5 seconds |
* estimate, results may vary. |
Our products accuracy meet DOT approval standard in the U.S and CE mark in Europe.
DECT™ (Dynamic Environmental Compensation Technology) enhances the stability and accuracy of our breathalyzers under dynamic environment conditions (eg: variance in temperature and humidity) to avoid false positive reading. DECT also effectively maintains the consistency of reading over time, even after long time of inactivity of the testers.
EVT™ (Electronic Valve Technology) automates the sensor to start collecting test sample only when a certain air pressure point produced by the blowing action is reached. This enhanced feature borrows the same idea from fuel cell breathalyzers, for the purpose to capture the test sample from deep lung for accurate measuring.
批發市場僅提供代購諮詢服務,商品內容為廠商自行維護,若有發現不實、不合適或不正確內容,再請告知我們,查實即會請廠商修改或立即下架,謝謝。