    Patient Monitor_N2 Specification TableBitmap
    Ward Monitor_N2
    Product Specifications
    Safety/Standard
     
    Physical specifications 
    Weight (Standard Configuration) 
    Size300(W)×270(H)×120(D)mm
       300(W)×410(H)×120(D)mm (with printer
    Display 
    Type and size12.1" Color TFT
    Resolution800*600 
    Number of trace6 traces 
    Sweep speed12.5mm/s,25mm/s,50mm/s 
    Display modesStandard display 
     Large-font display 
     Trend coexist display 
     OxyCRG dynamic view display 
    Drug does calculationYes 
    Standby modeYes 
    Opertion Environment: 
    Temperature0ºC to 40ºC 
    Relative Humidity85% (noncondensing) 
    Atmospheric pressure860hPa1060 hPa 
    Storage/Transportation 
    Temperature-20ºC to 60ºC 
    Humidity93% (noncondensing) 
    Atmospheric pressure860hPa1060 hPa 
    Electrical 
    AC input voltage100-240V 
    AC input frequency50/60Hz 
    AC input power100VA 
    Battery 
    TypeExchangeable Li-ion battery 
    Voltage14.8V 
    Maximum number of batteries1 
    Battery life2 hours with one battery 
    Charge time (Monitor switched off)7 Hours with 1 battery 
    Charge time (Monitor switched on)10Hours with 1 battery 
    Patient RangeNeonate, pediatric, and adult patients
    Alarms 
    CategoriesPhysical alarms and Technical alarms 
    PriorityHigh, Medium, and Low 
    Alarm sound levels0,1,2,3,4 
    NotificationVisual and Audible 
    Pausing1min, 2min, 3min 
    SettingLatch, Unlatch 
       
    Performance Specifications 
    Data Storage 
    Trend Graph 
    Reviewable ParametersHR,ST,SpO2,PR,NIBP,RR,TEMP 
    Resolution1s, 5s, 5min, 10min 
    Trend Data1 hour short trend @ 1s resolution 
     256 hours long trend @ 1min resolution 
    Trend Table 
    Reviewable ParametersHR,ST,SpO2,PR,NIBP,RR,T1,T2,TD 
    Resolution1,5,10,30,60min 
    Trend Data256 Hours trend date for all parameters 
    NIBP measurement400 Groups 
      
    Reviewable ParametersECG,SpO2,NIBP,RESP,TEMP,HR_H>180,HR_L<60, 
     SpO2<90%RR_L<10,RR_H>40, 
     TEMP_H>40ºC,TEMP_L<34ºC 
    ECG 
    Algorithm  
    Lead type3-Lead or 5-Lead selectable 
    3 leadwireI,II, or III 
    5 leadwireI,IIIIIVAVRAVLAVF 
    Gain×0.25,×0.5,×1,×2,Auto 
    Sweep speed12.5mm/s, 25mm/s, 50mm/s 
    Standardizing voltage1mV marker 
    Bandwidth(Surgery mode)1-20Hz 
    Bandwidth(Monitoring mode)0.5-40Hz 
    Bandwidth(Diagnostic mode)0.05-130Hz 
    Multi-lead display6 waveforms 
    Lead failIdentifies failed lead 
    AlarmsUser-selectable upper and lower heart rate limits 
    ECG derived HR  
    Heart Rate for Adult15-300BPM 
    Heart Rate for Neonate/Pediatric15-350BPM 
    Heart Rate Accuracy±1BPM or ±1%, whichever is greater 
    Heart Rate Resulotion1BPM 
    Notch50Hz, 60Hz 
    ST Segment  
    ST segment range-2.0mv to 2.0mv 
    ST alarm range-2.0mv to 2.0mv 
    ST segment accuracy-0.8mv to 0.8mv 
    ST segment error±0.02mv 
    Arrythmia type13 types 
    ST analysis2-lead measurement 
    Pace  
    Pace detectionYes 
    Pace rejection amplitude±2 mV±700mV 
    Pace rejection width0.1ms2ms 
    Pace rejection rise time10µs100µs 
    Temperature 
    ScaleºCelsius(C) or ºFahrenheit(F) 
    Probe typeYSI typs 
    ParametersT1,T2 and TD 
    TD(Temperature difference)Yes 
    Measurement range0~50ºC 
    Resolution0.1ºC 
    Accuracy±0.1ºC 
    Refreshing timeapproximately 1S 
    Pulse oximetry 
    SpO2  
    Measurement range1%~100% 
    Resolution1% 
    Accuracy±2%(70%-100%); unspecified(0-69%) 
    Alarm range0~100% 
    Pulse Rate  
    Measurement range20bpm300bpm 
    Resolution1bpm 
    Accuracy±3bpm 
    Alarm range0~254bpm 
    NIBP(non-invasive blood pressure) 
    Measurement techniqueOscillometric 
    Displayed parametersSystolic, diastolic and MAP(mean arterial pressure) 
    Measurement modeManual, Auto,STAT 
    Auto cycle time0-4 Hours 
    Measurement unitmmHg/kPa selectable 
    Range of Systolic pressureAdult     40-270mmHg 
     Pediatric40-200mmHg 
     Neonate40-135mmHg 
    Range of mean pressureAdult     20-235mmHg 
     Pediatric20-165mmH 
     Neonate20-110mmHg 
    Range of diastolic pressureAdult     10-215mmHg 
     Pediatric10-150mmHg 
     Neonate10-100mmHg 
    Accuracy5% 
    Resolution1mmHg 
    AlarmsSelectable upper and lower limits 
     for systolic, diastolic and mean pressure 
    Over-pressure protectionDouble safety protection 
    Respiration 
    Measurement techniqueRA-LL Impedance variation detection 
    RangeAdult7~120rpm 
     Pediatric/Neonate: 7~150rpm 
    Apnea alarmYes, 10s,15s,20s,25s,30s,35s,40s selectable 
    Sweep speed6.25mm/s, 12.5mm/s, 25mm/s 
    Gain0.25, 0.5, 1, 2, 4 
    Standard Configuration:ECG,SPO2,NIBP,TEMP,PR/HR   
    Optional Functions:Etco2,2IBP,Masimo SPO2,Wried and Wireless Central Station Systems ,Printer
    Recorder 
    TypeThermal dot array 
    Vertical resolution8dot/mm 
    Number of waveform channels2(standard), 1,3(optional) 
    Paper width50mm 
    Paper length13.5m 
    Paper speed25mm/s 
    IBP 
    Channels1 or 2 selectable 
    Measuremen range-10~300mmHg 
    Resolution1mmHg 
    Accuracy±1mmHg or ±2%, whichever is greater(without sensor) 
    Pressure namesART, PA, CVP, RAP, LAP, ICP, P1, P2 
    Alarm range-10~300mmHg 
    Pressure transducer  
    Sensitivity5µv/V/mmHg 
    Impedance range300-3000Ω 
    ETCO2 
    Mainstream CO2  
    Measurement range0-150mmHg 
    Accuracy0 to 40mmHg       ±2mmHg 
     41 to 70mmHg     ± 5% of the reading 
     71 to 100mmHg   ±8% of the reading 
     101 to 150mmHg ±10% of the reading 
    RR range0 to 150rpm 
    Accuracy1rpm 
    Response time<60ms 
    Sidestream CO2  
    Measurement range0-150mmHg 
    Accuracy0 to 40mmHg       ±2mmHg 
     41 to 70mmHg     ± 5% of the reading 
     71 to 100mmHg   ±8% of the reading 
     101 to 150mmHg ±10% of the reading 
    Sample flowerate50ml/min 
    Accuracy±15% or 15ml/min,whichever is greater 
    Warm-up time<1min,enter the iso accuracy mode 
     After 1 min,enter the full accuracy mode 
    RR range0-120rpm 
    RR accuracy±2 rpm 
    Response time 