1. Product Dimensions & Outline Drawing & marking(Unit:mm)
Model | A | B | C | D | E | Lead |
MAX | MAX | TYP | MIN | MAX | Φ | |
TRB900 | 24.2 | 32.9 | 10.2 | 7.6 | 3.0 | 0.80 |
2. Electrical Properties
Model | IH (A) | IT (A) | Vmax (v) | Imax (A) | Ttrip | Pdtyp (W) | Rmin (Ω) | Rmax (Ω) | R1max (Ω) | |
(A) | (S) | |||||||||
TRB900 | 9.00 | 18.00 | 30 | 40 | 40 | 20.0 | 4.00 | 0.004 | 0.010 | 0.015 |
IH: Holding Current: maximum current at which the device will not trip in 25℃ still air.
IT: Tripping Current minimum current at which the device will trip in 25℃still air.
Vmax: Maximum voltage device can withstand without damage at rated current.
Imax: Maximum fault current device can withstand without damage at rated voltage.
Ttrip: Maximum time to trip(s) at assigned current.
Pdtyp: Rated working power.
Rmin: Minimum resistance of device prior to trip at 25℃.
Rmax: Maximum resistance of device prior to trip at 25℃.
R1max:Maximum resistance of device measured one hour after tripping at 25℃.
3. Thermal Derating Chart – Ihold(Amps)
Model | Ambient Operating Temperature | ||||||||
-40℃ | -20℃ | 0℃ | 25℃ | 40℃ | 50℃ | 60℃ | 70℃ | 85℃ | |
TRB900 | 13.00 | 11.70 | 10.30 | 9.00 | 7.47 | 6.93 | 6.12 | 5.49 | 4.68 |
4. Typical time to trip at 25℃