| Fetal & Maternal Monitor_DS120C Specification Table | Bitmap
| |||||||
| Product Specifications | ||||||||
| Safety/Standard | ||||||||
| Physical specifications | ||||||||
| G .Weight | 9.0KGS | |||||||
| Weight(Maximum) | ||||||||
| Size | 300mm x 500mm x 350mm | |||||||
| Display | ||||||||
| Type and size | 12.1” high resolution color TFT LCD display | |||||||
| Resolution | ||||||||
| Number of trace | 4 traces | |||||||
| Sweep speed | 12.5mm/s,25mm/s,50mm/s | |||||||
| Opertion Environment: | ||||||||
| Temperature | 5ºC to 40ºC | |||||||
| Relative Humidity | ≤80% (noncondensing) | |||||||
| Atmospheric pressure | ||||||||
| Storage/Transportation | ||||||||
| Temperature | -20ºC to 60ºC | |||||||
| Humidity | ≤93% (noncondensing) | |||||||
| Atmospheric pressure | ||||||||
| Electrical | ||||||||
| AC input voltage | 100-240V | |||||||
| AC input frequency | 50/60Hz | |||||||
| AC input power | ||||||||
| Battery: Rechargeable built-in battery, above 2 hours for continuous working | ||||||||
| Patient Range | ||||||||
| Neonate, pediatric, and adult patients | ||||||||
| Features & Benefits: | ||||||||
| 1. 9 standard parameters: ECG, RESP, NIBP, SPO2, 1-TEMP, PR/HR, FHR, TOCO, Fetal movement detection. | ||||||||
| 2. 12.1” high resolution color TFT LCD display. Simple and friendly operating display interface. | ||||||||
| 3. 9-wafer impulse ultrasound transducer, configured with special HR self correlation reading algorithm to ensure | ||||||||
| correct and reliable fetal heart rate (FHR) measurement. | ||||||||
| 4. Large built-in chargeable battery provides convenience for patients’ moving. | ||||||||
| 5. Playback and browse function for history waveform and monitor data record. | ||||||||
| 6. Optional printing output function, alarm triggers printing. | ||||||||
| 7. Auto double alarm with audible and visible signals. | ||||||||
| 8. Anti-defibrillation, anti-interference from high frequency electric knife. | ||||||||
| 9. Pace-maker detection. | ||||||||
| 10. A full-synchronistic leads, multi-channel ECG display. | ||||||||
| 11. Indication of incorrect manipulation and malfunction analysis. | ||||||||
| 12. Unique accessory management cabinet. | ||||||||
| Performance Specifications | ||||||||
| ECG | ||||||||
| Lead mode: | 5 –lead, RA, LA, RL, LL, V | |||||||
| lead selection: | I, II, III, avR, avL, avF, V, MCL | |||||||
| Sweep speed: | 12.5mm/s, 25mm/s, 50mm/s | |||||||
| Heart Rate range: | 15~300bpm; | |||||||
| Accuracy: | ±1bpm or ±1%, whichever is greater | |||||||
| Resolution: | 1bpm | |||||||
| Filter: | Surgery mode: 1~25Hz | |||||||
| Monitor mode: 0.5~35Hz | ||||||||
| Diagnostic mode: 0.05~100Hz | ||||||||
| Scaling signal: | 1mV, ±3% | |||||||
| Alarm range: | 20~250bpm | |||||||
| S-T segment detection: | Measurement range:-2.0mV~ +2.0mV | |||||||
| Alarm Range: -2.0mV~ +2.0mV | ||||||||
| NIBP(non-invasive blood pressure) | ||||||||
| Operation mode: | Manual/Automatic | |||||||
| Auto measurement time: | Adjustable (1~120min) | |||||||
| Measurement Unit: | mmHg/Kpa selectable | |||||||
| Measurement types: | Systolic, Diastolic, Mean | |||||||
| Over-pressure protection: | Double safety protection | |||||||
| SPO2 | ||||||||
| Measurement range: | 0~100% | |||||||
| Resolution: | 1% | |||||||
| Accuracy: | ±2% (80-100%); 1-60% unspecified | |||||||
| Alarm range: | 1~100% | |||||||
| RESP: | ||||||||
| Method: | Thoracic impedance | |||||||
| Measurement range: | 1~99rpm | |||||||
| Alarm range: | 1~99rpm | |||||||
| Solution: | 1rpm | |||||||
| Accuracy: | ±2rpm | |||||||
| TEMP | ||||||||
| Measurement Range: | 25~45℃ | |||||||
| Resolution: | 0.1℃ | |||||||
| Accuracy: | ±0.1℃ | |||||||
| Channel: | 1-channel | |||||||
| PR | ||||||||
| Measurement Range: | 15~300bpm | |||||||
| Resolution: | 1bpm | |||||||
| Accuracy: | 1bpm | |||||||
| Alarm range: | 15~300bpm | |||||||
| TOCO | ||||||||
| Measurement Range | 0~100 unit | |||||||
| Non-linearity tolerance | ±8% | |||||||
| Accuracy: | 1unit | |||||||
| Auto-zero function | Yes | |||||||
| FHR | ||||||||
| Measurement Range | 60~210BPM | |||||||
| Accuracy: | ±2rpm | |||||||
| Resolution: | 1bpm | |||||||
| Transducer | 9-wafer impulse ultrasound transducer | |||||||
| Ultrasound output intensity | ﹤3mW/cm2 | |||||||
| Ultrasound working frequency | 1.0MHz | |||||||
| Fetal movement record | ||||||||
| Manual control button label. | ||||||||
| Optional Functions:Thermal printers(50mm) | ||||||||