ADVANCED ENGINEERING
MED-460
SILICONE FLUID
• A clear liquid copolymer consisting of dimethylisiloxane and trifluoropropylmethylsiloxane to provide a lubricious and/or hydrophobic coating, for lubricating the surfaces of molded dimethyl silicone elastomer parts
• Available in standard viscosities of: 350 cP, 1,000 cP, and 12,500 cP
• Custom viscosities available upon request
Applications
• For applications requiring a material that is highly water repellent and resists decomposition from heat and oxidation
• Has reduced solubility, good wetting properties and good lubricative characteristics in contact with plastics, rubber and skin
NuSil Technology's MED-460 may be considered for use in human implantation for a period of greater than 29 days.
Typical Properties | Result | ASTM | NT-TM | ||
Uncured: | 350 cP | 1,000 cP | 12,500 cP | ||
App earance | Translucent | Translucent | Translucent | ASTM D2090 | 002 |
Volatile Content | <0.2 % | <0.2 % | <0.3 % | ASTM D2288 | 004 |
Refractive Index | 1.382 | 1.382 | 1.383 | ASTM D1218, D1747 | 018 |
Tissue Culture (Cytotoxicity Testing) | Pass | Pass | Pass | USP <87>, ISO 10993-5 | 061 |
Instructions for Use
Packaging2 Ounce (57 g)
1 Pint (455 g)
1 Gallon (3.64 kg)
5 Gallon (18.2 kg)
Warranty
36 MonthsApplication
Apply directly to surfaces by dipping, spraying, brushing, or wiping. When a very thin film is desired, dilute to 1-5% weight silicone solids in a compatible solvent. Apply this solution to a surface using the above techniques. After applying, allow sufficient time for the solvent to evaporate.
Although MED-460 fluid possesses excellent lubricative characteristics, it may not provide satisfactory lubrication in load-bearing situations, especially those involving metal-to-metal contact.
Thin films of MED-460 fluid on plastics, metal and glass provide a temporary, water-repellent barrier. On materials resistant to thermal distortion, such as glass, ceramics, and metals, this fluid film can be converted to a highly durable hydrophobic film by heating the treated surface. Heating 2 hours at 250????????8????????3C (482????????8????????3F), 1 hour at 276????????8????????3C (536????????8????????3F) or 30 minutes at 300????????8????????3C (572????????8????????3F) is satisfactory.
FDA MASTER FILE
A Master File for MED-460 has been filed with the U.S. Food and Drug Administration. Customers interested in authorization to reference the Master File must contact NuSil Technology.
REACh COMPLIANCE
MED-460 is compliant with the Registration, evaluation, and Authorization of Chemicals (REACh) regulation (European unio 1907/2006). MED-460 does not contain any of the chemicals or substances identified as Substances of Very High Concern (SVHC) by the European Chemicals Agency (ECHA), which oversees REACh compliance.
Please contact NuSil Technology's Regulatory Compliance department with any questions or for further assistance.
Warnings about Product Safety
NuSil Technology LLC believes the information and the data contained herein are accurate and reliable. However, the user is responsible to determine the material's suitability and safety of use. NuSil Technology LLC cannot know each application's specific requirements and hereby notifies the user that it has not tested or determined this material's suitability or safety for use in any application. The user is responsible to adequately test and determine the safety and suitability for their application and NuSil Technology LLC makes no warranty concerning fitness for any use or purpose. NuSil Technology LLC has completed no testing to establish safety of use in any medical application. NuSil Technology LLC has tested this material only to determine if the product meets the applicable specifications. (Please contact NuSil Technology LLC for assistance and recommendations when establishing specifications.) When considering the use of NuSil Technology LLC products in a particular application, review the latest Material Safety Data Sheets and contact NuSil Technology LLC with any questions about product safety information.
Do not use any chemical in a food, drug, cosmetic, or medical application or process until having determined the safety and legality of the use. The user is responsible to meet the requirements of the U.S. Food and Drug Administration and any other regulatory agencies. Before handling any other materials mentioned in the text, obtain available product safety information and take the necessary steps to ensure safety of use.
Specifications
Do not use the typical properties shown in this technical profile as a basis for preparing specifications. Please contact NuSil Technology LLC for assistance and recommendations in establishing particular specifications.
Patent Warning
NuSil Technology LLC disclaims any expressed or implied warranty against the infringement of any patent. NuSil Technology LLC does not warrant the use or sale of the products described herein will not infringe the claims of any United States' or other country's patents covering the product itself, its use in combination with other products or its use in the operation of any process.
Warranty Information
NuSil Technology LLC's warranty period is 12 months from the date of shipment when stored below 40°C in original unopened containers. Unless NuSil Technology LLC provides a specific written warranty of fitness for a particular use, NuSil Technology LLC's sole warranty is that the product will meet NuSil Technology LLC's then current specification. NuSil Technology LLC specifically disclaims any other expressed or implied warranty, including warranties of merchantability and fitness for use. The exclusive remedy and NuSil Technology LLC's sole liability for breach of warranty is limited to refund of purchase price or replacement of any product shown to be other than as warranted. NuSil Technology LLC expressly disclaims any liability for incidental or consequential damages.
新手教學