產品類型:激光管 | 是否進口:是 | 品牌:德國歐司朗 |
型號:LJ528NM120MW | 封裝:to18 | 工作溫度范圍:-40~75(℃) |
針腳數:3 |
·Features
1)Maximum optical power output :120mW(cw)
2)High power (pulse MAX 200mW)
3)Wavelength :TYP=520nm
4)High coupling efficiency,The ellipticity (Θ丄/Θ〢)is close to 5.
5)3.8mm package.TO-38
·Absolute Maximum Ratings
Parameter/Symbol -------Rating/Unit
1)Light output power/cw-----120mw
2)Light output power/pulse--200mw
3)Reverse voltage/VRL------- 2V
4)Case temperature/Tc------- 0~+75℃
5)Storage temperature/Tstg-- -40~+85℃
·Electrical/optical Characteristics(Tc=25℃)
Parameter/---Symbol-Testconditions--Min/Typ/Max-Unit
1)Threshold current/ith-----cw-------_-_/60_/75_-mA
2)Operating current/iop-cw,po=120mw--_-_/200/240-mA
3)Operating voltage/vop-cw,po=120mw--_-_/6.7/8.0-V
4)Slope efficiency/--h--cw,po=120mw--_-_/_-_/_-_-mw/mA
5)Peak wavelength/--λp--cw,po=120mw--510/515/530-nm
6)Beam divergence angle-cw,po=120mw--16_/22_/25_-(parallel/Θ丄)
7)Beam divergence angle-cw,po=120mw--_4_/_7_/11_-(perpendicular/Θ〢)
半導體激光二極管LD在工作中易退化的四大原因
半導體激光二極管LD本身比較嬌嫩,從它剛出現就麵臨著使用壽命的問題,經過不斷的研究改進,目前激光二極管LD的壽命可達1萬小時,以能夠滿足光纖通信使用的需要。激光二極管LD在工作中易退化的原因主要有以下幾個方麵:
1,半導體激光二極管LD的管芯極小,工作電流密度和光功率密度很高,而作為激光物質的半導體單晶材料又較容易發生缺陷,這些缺陷在電和光的作用下逐漸發展,從而引起器件性能的退化。
2,半導體激光二極管LD的鏡麵是用解理工藝形成的,鏡麵本身受到環境條件影響而污染也會也會導致激光二極管LD性能退化。
3,激光二極管LD的管芯焊接也是關鍵技術,管芯焊在熱沉之上,而有源去距離熱沉隻有幾微米;半導體激光二極管LD工作會發熱,如果焊料太多,受熱時會發生緩慢的攀移,使半導體激光二極管LD發生短路,導致激光二極管LD退化。
4,隨著工作時間的延長,激光二極管LD的閾值電流會緩慢增加,從而導致激光二極管LD退化。