1. 3 Protection: (保護功能) 1.3.1 Table 8 DC output Over Voltage Protection. (輸出過壓保護) Output Voltage | Max .Over Voltage | Comments | +V1(+12V) | / | Power supply latch into non-output state | | | | | | |
Note:The power supply shall be test at max.AC voltage (264Vac) and min .load or no load. 1.3.2Table 9 DC Output Over current Protection. (輸出過流保護) Output Voltage | Over Current | Comments | +V1(+12V) | 2Atyp | Power supply restart | | | | | | | | | |
Note: the over current protection should be test at other fo dc output at rated load . 1.3.3Table 10 DC output Short Circuit Protection.(輸出短路保護) Output Voltage | Comments | +V1(+12V) | Power supply restart | | | | | | |
Note: the over current protection should be test at other fo dc output at rated load . 1.3.4. Reset After Shutdown.(保護功能復位) If the power supply latches into shutdown state due to fault condition on its output protection, the power supply shall return to normal operation only after the fault hasbeen removed and the Ps-on or Ac input has been cycled off /on with a minimum off time of 2second. |