Temperature sensor TS-1
Operating
Instructions
The ROPEX temperature sensor TS-1 is used for
measuring temperatures in sealing applications. With
the short response time the sensor is suitable for
measurements in high dynamic sealing applications.
The sensor is easiest to install. The foil sensor is
embedded between two paper thin, glass reinforced
high temperature polymer laminates which both
support and electrically insulate the foil section as well
as provide a flat surface for cementing.
Technical data
Thermocouple type | K-Type |
Maximum Temperatures | Continuous:260℃ 10 hours, short duration:370℃ The maximum temperatures depend on the ambient conditions,assembly, requested accuracy and life time. The described values ar overview values only. |
Response time | 10...20ms, when "grounded"or "cemented" to surface. (Time which is necessary to reach approximately 60% of the realtemperature after a temperature jump occured) |
Accuracy | 1,1℃ or 0,4% of the measured temperature (higher value is valid) Specification according "class 1", SLE |
Cable type | Glass braid insulated 30 gage thermocouple wire |
Pin assignment | Yellow cable:Nickel-Chromium (Chromel),POS ( + ) Red cable:Nickel-Aluminium (Alumel),NEG ( ¨C ) |
Cable length | 1meter |
Assembly / Bonding | Epoxy adhesives can be used when bonding the sensor to a surface. A Cemet high temperature glue shall not be used. This glue damages the isolationpad of the sensor. |