產品名稱: QY型充油式潛水電泵
口 徑(進口/出口):38-152mm
流 量:8.4-100m3/h
揚 程:6-60m
型號 | 額定流量 | 額定揚程 | 配管 | 配用功率 | 轉速 | 額定電壓 |
m3/h | m | mm | KW | r/min | V | |
QY8.4-40-2.2 | 8.4 | 40 | 50 | 2.2 | 2860 | 380 |
QY15-26-2.2 | 15 | 26 | 50 | |||
QY25-17-2.2 | 25 | 17 | 63 | |||
QY40-12-2.2 | 40 | 12 | 76 | |||
QY65-7-2.2 | 65 | 7 | 100 | |||
QY100-4.5-2.2 | 100 | 4.5 | 150 | |||
QY15-36-3 | 15 | 36 | 50 | 3 | ||
QY25-26-3 | 25 | 26 | 63 | |||
QY40-16-3 | 40 | 16 | 76 | |||
QY65-10-3 | 65 | 10 | 100 | |||
QY100-6-3 | 100 | 6 | 150 | |||
QY160-4-3 | 160 | 4 | 150 | |||
QY260-3.5-4 | 260 | 3.5 | 200 | 4 | ||
QY200-4.5-4 | 200 | 4.5 | 150 | |||
QY65-14-4 | 65 | 14 | 100 | |||
QY40-21-4 | 40 | 21 | 76 | |||
QY25-32-4 | 25 | 32 | 63 | |||
QY25-38/2-4 | 25 | 38 | 63 | |||
QY12.5-50-4 | 12.5 | 50 | 50 | |||
QY12.5-72/4-4 | 12.5 | 72 | 50 | |||
QY25-45/3-5.5 | 25 | 45 | 63 | 5.5 | ||
QY10-78/3-5.5 | 10 | 78 | 50 | |||
QY200-8-5.5 | 200 | 8 | 150 | |||
QY260-6-5.5 | 260 | 6 | 200 | |||
QY65-18-5.5 | 65 | 18 | 100 | |||
QY40-28-5.5 | 40 | 28 | 76 | |||
QY25-40-5.5 | 25 | 40 | 63 | |||
QY18-64/3-5.5 | 18 | 64 | 63 | |||
QY65-28-7.5 | 65 | 28 | 100 | 7.5 | ||
QY40-38-7.5 | 40 | 38 | 76 | |||
QY25-50-7.5 | 25 | 50 | 63 | |||
QY200-10-7.5 | 200 | 10 | 150 | |||
QY10-100/4-7.5 | 10 | 110 | 50 | |||
QY260-8-7.5 | 260 | 8 | 200 | |||
QY18-126/6-11 | 18 | 126 | 63 | 11 | ||
QY10-160/6-11 | 10 | 160 | 50 |
五、使用註意事項:
2、潛水泵配用的出水管內徑應和電泵口徑相配。
序號 | 原 因 | 處 理方法 |
1 2 3 4 5 6 7 8 | 電源電壓過低 電源斷電 電泵葉輪卡牢 電纜斷裂 電纜電壓降過大 電纜插頭損壞 電機的三相電纜有一相不通 電機定子繞組壞 | 必須調整到342~418伏。 找出斷電原因。 拆開導向件,消除垃圾。 按規格進行調換。 必須使用較粗的電紱。 調換新的插頭。 應該檢查開關線頭及出線有否損壞,發現損壞應該更新 重新下線,進行大修 |
原因 | 處進方法 |
空氣開關跳開熔絲燒斷 電源斷電 定子繞組燒壞 葉輪卡牢 | 應檢查線路故障或重新換熔絲。 找出斷電原因,消除故障,恢復供電後再啟動。 重修。 消除雜物,排除故障。 |
批發市場僅提供代購諮詢服務,商品內容為廠商自行維護,若有發現不實、不合適或不正確內容,再請告知我們,查實即會請廠商修改或立即下架,謝謝。