Handheld Use |
|
- Fits in one hand for easy use.
- Superior LCD Display visibilty and viewing angle.
|
Display Infomation |
|
Easy to read and manage data with personal computer | | - When the DP700B/E is connected to a USB port, the PCrecognizes the DP700 as an outside source and has the ability to read the thermometer fs data.
* OS : Windows Me/2000/XP - Measured data can be stored in the file in the CSV format.
|
| | |
Comment (Max. 11 characters) | Measured date and time Month / Day, Time or Day / Month, Time ( selecable ) |
| - DP-700B/E stores up to 99 points of logging temperature data including comment, measured date and time.
|
|
Specifications | Input and Measuring range | Universal input
Thermocouple K | -200 to +1372°C (Resolution : 1°C) -328 to +2501°F (Resolution : 1°F) -199.9 to +999.9°C (Resolution : 0.1°C) -199.9 to +999.9°F (Resolution : 0.1°F) | Thermocouple J | -200 to +1200°C (Resolution : 1°C) -328 to +2192°F (Resolution : 1°F) -199.9 to +999.9°C (Resolution : 0.1°C) -199.9 to +999.9°F (Resolution : 0.1°F) | RTD Pt100 | -199.9 to +999.9°C (Resolution : 0.1°C) -328 to +1562°F (Resolution : 1°F) -199.9 to +850.0°C (Resolution : 0.1°C) -199.9 to +999.9°F (Resolution : 0.1°F) |
* It is connected type "6C" connector made in RKC. | Sampling time | 0.5 sec. | Measuring accuracy | ± (0.1% of reading + 1digit) or ±0.3°C (Whichever is larger) Cold-junction tempeature compensation error ± 0.5°C ( 5 to 40°C ) ± 1.0°C ( -20 to 5°C, 40 to 50°C ) Ambient temperature influence ± 0.01% of span /°C ( 5 to 40°C ) ± 0.02% of span /°C ( -20 to 5°C, 40 to 50°C) | Display | Reflective FSTN LCD Measuring value (PV) : 4-digit, Logging (Recording) No : 4-digit, Total number of logging data: 4-digit, Message : 68 x 8 dots Logging execution : Lit during execution Burnout (Sensor broken) : Lit when the sensor is broken. Remaining battery service life : The remaining battery service life is indicated in three steps. Temperature unit : 12 x 8 dots ( °C / °F ) | Data logging ( recording ) | Recording method : | Manual log mode : Can be manually recorded in the memory. Interval log mode : Can be automatically recorded ( in a set interval ) |
Interval time : | 0 ( Manual mode), 1 to3600 sec. |
Recording items : | Measured temperature, Date, Time, Tag name, User No. |
Recording capacity : | DP-700A : Max. 99 logs DP-700B : Max. 9999 logs |
Memory backup : | DP-700A : Backed up by SRAM. The recorded data may be lost if battery service life has expired or the battery is replaced. | | DP-700B : Backed up by EEPROM Number of writing : Approx. 100,000 times Data retaining period : Approx. 10 yeares |
| Temperature gradient indication | The evaluation points of high and low temperature are set. When within the evaluation points, "" is displayed while when out of the evaluation point, "" is displayed. | Tag number function | Number of maximum registration : | DP-700A : 5 tags DP-700B : 99 tags |
Registration items : | Tag name, evaluation points of high and low temperature. |
Tag neme : | 11 characters ( Numeral, Alphabets, Symbols ). |
Memory backup : | Same as Memory backup of data logging |
| User name function | Any user name can be registered for each user number. Logging data can store into register name. Number of maximum registration : 99 names, Number of character : 11 characters (Numeral, Alphabets, Symbols) Memory backup: Same as Memory backup of data logging | USB function ( only for DP-700B ) | Interface : USB (Universal Serial Bus) Ver2.0 Communication speed : Full Speed compliant Connector type : USB series Mini-B Power supply : Bus power ( The power is supplied from the USB port on the PC side. ) Device class: Mass Storage Class (Bulk-only Transport) | Waterproof and dustproof | DP-700A : IP67 DP-700B : IP54 | Other function | Peak and bottom hold PV bias : -99.9 to +99.9°C ( °F ) PV digital filter : 0 to 100 sec ( 0 : OFF ) Calender timer ( year, month, date, hour, minute ) Operation lock, Self-diagnostic | Power supply | Type LR6 ( based on IEC and JIS ) alkaline battery, One battery Battery life : Approx. 400 hours ( Continuous operating time, Around the ambient temperature 23°C ) | Ambient temperature | -20 to +50°C | Ambient humidity | 5 to 95%RH ( Absolute humidity : Max. W.C 29g/m3 dry air at 101.3kPa ) | Weight | Approx. 140g ( including LR6 Alkaline battery) | Accessories | LR6 ( IEC and JIS ) Alkaline battery, Strap USB cable 1m ( only DP-700B ) |
|
|
External Dimension |
Unit : mm |
Handheld type Temperature Sensor | Example |
| | ST-23-6CFor static surface | Temperature range : 0 to 300°C ( Non-condensing ) | | Caution: Connector geometry is different from conventional DP-350 / DP-500 use. | |
| ST-23L-6CFor static surface | Temperature range : 0 to 300°C ( Non-condensing ) | | Caution: Connector geometry is different from conventional DP-350 / DP-500 use. | |
| ST-29-6CFor static surface | Temperature range : 0 to 800°C ( Non-condensing ) | | Caution: Connector geometry is different from conventional DP-350 / DP-500 use. | |
| JB-16-6C For use with semi-solids, viscous material and liquids | Temperature range : 0 to 650°C ( ø 1.6 ) 0 to 750°C ( ø 3.2 ) | Specify a diameter ( ø d ) .
| Caution: Connector geometry is different from conventional DP-350 / DP-500 use. | |
| JB-15-6C For use with semi-solids, viscous material and liquids | Temperature range : 0 to 400°C | | Caution: Connector geometry is different from conventional DP-350 / DP-500 use. |
|
以下為DP-700專用連接線W-ST50A-1000-6C及微型貼片傳感器ST-50資料:
新手教學