Full-automatic Arm Blood Pressure Monitor
Instruction Manual
TABLE OF CONTENTS
Introduction
Safety Information
Before Taking a Measurement
Know Your Unit
Unit Display
BatteryInstallation
Applying the Cuff on the Left Arm
Taking a Measurement
Using the Memory Function
Change Pressure Display Unit
Specifications
Care and Maintenance
Statement
Warranty Information
About Blood Pressure
INTRODUCTION
Thank you for purchasing Full-automatic Arm Blood Pressure Monitor.
Your new digital blood pressure monitor uses the oscillometric method of blood pressure measurement. This means the monitor detects your blood’s movement through your brachial artery and converts the movements into a digital reading. An oscillometric monitor does not need a stethoscope so the monitor is simple to use.
The Arm blood pressure monitor comes with the following components:
* Monitor
* Arm Cuff
* 4 “AAA” Batteries
* Stylish Zipper Case
* Instruction Manual
SAFETY INFORMATION
To assure the correct use of the product, basic safety measures should always be followed including the note and cautions listed in this instruction manual.
SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL
This manual uses the following icons to call attention to specific instructions or guidance.
NOTE:Indicates something you must do to use your device
correctly and effectively.
CAUTION:Warns you that not following these instructions can cause injury, harm or serious damage.
OPERATING THE DEVICE
▲ Contact your physician for specific information about your blood pressure. Self-diagnosis and treatment using measured results may be dangerous. Follow the instructions of your physician or licensed healthcare provider.
▲ If battery fluid should get in your eyes, immediately rinse with plenty of clean water. Contact a physician immediately.
▲ Read all of the information in this instruction manual before operating the unit.
▲ Operate the device only as intended. Do not use the device for any other purpose.
▲ Do not use a cellular phone near the device. It may result in an operational failure.
▲ Dispose of the device, components and optional accessories according to
applicable local regulations. Unlawful disposal may cause environmental pollution.
▲Inflating to a higher pressure may result in bruising where the cuff is applied. Operate the device only as intended. Do not use the device for any other purpose.
▲Do not plug or unplug the power cord into the electrical outlet with wet hands.
▲Do not submerge the device or any of the components in water.
▲Do not subject the monitor to strong shocks, such as dropping the unit on the floor.
▲ Store the device and the components in a clean, safe location.
▲ Use only 1.5V alkaline batteries with this device.
▲ Do not use other types of batteries. This may damage the unit.
BEFORE TAKING A MEASUREMENT
To ensure a reliable reading, following these recommendations:
1. Avoid eating, smoking, exercising, and bathing for 30 minutes before taking a measurement. Please have a rest for at least 15 minutes before taking the measurement.
2. Stress raises blood pressure. Avoid taking measurements during stressful times.
3. Measurements should be taken in a quiet place.
4. Remove tight-fitting clothing from your arm
5. Sit in a chair with your feet flat on the floor. Rest your arm on a table so that the cuff is at the same level as your heart.
6. Remain still and do not talk during the measurement.
7. Keep a record of your blood pressure and pulse readings for your physician. A single measurement may not provide an accurate indication of your true blood pressure. You need to take and record several readings over a period of time. Try to measure your blood pressure at about the same time each day for consistency.
8. Wait 2-3 minutes between measurements.
KNOW YOUR UNIT
|
UNIT DISPLAY
Icons and numeric displays on your device assist you in taking quick and accurate readings
ICON/DISPLAY | INDICATES… | |
| The systolic BP, read in mmHg, display immediately beside this symbol. | |
| The diastolic BP, read in mmHg, display immediately beside this symbol. | |
| Unit of measurement for SYS, DIA | |
| Heart rate, in beats per minute | |
| 00 | Over pressure error: cuff pressure>330mmHg |
01 | Cuff pressure unstable when monitor initial | |
02 | Inflation error | |
03 | Deflation speed too low | |
04 | Deflation speed too fast | |
05 | Measurement error | |
06 | Hand move error in measurement | |
07 | Memory operation error | |
| When the batteries power are too low |
HEARTBEAT SYMBOL/HYPERTENSION INDICATOR
TAKING A MEASUREMENT
The Heartbeat Symbol () flashes on the display during the measurement. The Heartbeat Symbol () flashes at every heartbeat. When the measurement is complete.
The American Heart Association recommends the following guideline for upper limit of normal for home blood pressure readings: AHAHome Guideline for Upper Limit of Normal BP
Systolic Blood Pressure | ≤140mmHg |
Diastolic Blood Pressure | ≤90 mmHg |
This is a general guideline because blood pressure depends on age and morbidity. The AHA recommends a lower home blood pressure goal for certain patients, including diabetic patients, pregnant women, and patients with renal failure.
The monitor is not intended to be a diagnostic device.
Contact your physician for specific information about your blood pressure. Self-diagnosis and treatment using measured results may be dangerous. Follow the instructions of your physician or licensed healthcare provider.
BATTERYINSTALLATION
1. Press the indicator on the battery cover and slide the cover off in the direction of the arrow.
2. Install 4 “AAA” size batteries so the + (positive) and - (negative) polarities
match the polarities of the battery compartment as indicated.
3. Replace the battery cover.